{"id":"product-c2dc8714f0ef22ab93b9507f","slug":"hayward-sp1580x15vsp-93b9507f","kind":"model","name":"Hayward PowerFlo VS 300","manufacturer":{"id":"company-97e7f88c5898532e2bf572c9","name":"HAYWARD INDUSTRIES, INC."},"manufacturerCountryCode":"US","brandId":"brand:hayward","brand":"Hayward","modelNumber":"SP1580X15VSP","partNumbers":[],"gtins":["0610377366946"],"wics":["04.1.001"],"relevance":"water","lifecycleStatus":"active","tier":0,"completeness":0.88,"href":"/api/v1/products/hayward-sp1580x15vsp-93b9507f","web":"/en/products/hayward-sp1580x15vsp-93b9507f","aliases":[],"familyId":"family-83faae85e583186e136960d4","familySlug":"hayward-powerflo-vs-300-136960d4","officialUrl":null,"attributes":[{"key":"product_type","label":"Product Type","value":"Above-Ground (Non-Self-Priming) Pool Filter Pump","valueType":"string","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"}},{"key":"motor_design","label":"Motor Design","value":"Variable-speed","valueType":"string","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"}},{"key":"reported_wef_kgal_kwh","unit":"kgal/kWh","label":"Weighted Energy Factor (WEF) (kgal/kWh)","value":10.851,"valueType":"number","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"}},{"key":"minimum_wef","label":"Minimum WEF for Federal Standard","value":"4.45","valueType":"string","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"}},{"key":"flow_gpm_at_low_speed_measurement_point","label":"Flow (GPM) at low speed measurement point","value":25.01,"valueType":"number","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"}},{"key":"head_fth20_at_low_speed_measurement_point","label":"Head (ftH20) at low speed measurement point","value":5.1,"valueType":"number","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"}},{"key":"rpm_at_low_speed_measurement_point","label":"RPM at low speed measurement point","value":"1362.56","valueType":"string","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"}},{"key":"power_w_at_low_speed_measurement_point","label":"Power (W) at low speed measurement point","value":86.97,"valueType":"number","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"}},{"key":"flow_gpm_at_high_speed_measurement_point","label":"Flow (GPM) at high speed measurement point","value":51.77,"valueType":"number","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"}},{"key":"rpm_at_high_speed_measurement_point","label":"RPM at high speed measurement point","value":2774.36,"valueType":"number","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"}},{"key":"head_ft_h20_at_high_speed_point","label":"Head (ft.H20) at high speed point","value":22.05,"valueType":"number","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"}},{"key":"power_w_at_high_speed_measurement_point","label":"Power (W) at high speed measurement point","value":"484.55","valueType":"string","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"}},{"key":"standby_average_power_w","unit":"W","label":"Standby Average Power (W)","value":3,"valueType":"number","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"}},{"key":"motor_construction","label":"Motor Construction","value":"Electronically-commutated Motor","valueType":"string","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"}},{"key":"hydraulic_horsepower_hhp","unit":"HHP","label":"Hydraulic Horsepower (HHP)","value":0.55,"valueType":"number","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"}},{"key":"rated_horsepower_hp","unit":"HP","label":"Rated Horsepower (HP)","value":1.1,"valueType":"number","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"}},{"key":"freeze_protection","label":"Freeze Protection","value":"No","valueType":"string","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"}},{"key":"connected_functionality","label":"Connected Capable","value":"No","valueType":"string","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"}},{"key":"date_available_on_market","label":"Date Available On Market","value":"2018-10-15T00:00:00.000","valueType":"string","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"}},{"key":"markets","label":"Markets","value":"United States, Canada","valueType":"string","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"}}],"certifications":[{"name":"EPA ENERGY STAR certified product","issuer":"U.S. Environmental Protection Agency","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","validFrom":"2021-07-12","identifier":"2381912","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"}}],"status":"active","provenance":{"name":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"},"wics":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"},"brand":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"},"gtins":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"},"relevance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"},"attributes":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"},"familyName":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"},"modelNumber":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"},"manufacturer":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"},"certifications":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"},"manufacturerName":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2381912","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2381912"}},"sourceCoverage":[{"sourceId":"epa-energy-star-water-products","lastSeenAt":"2026-07-17T01:55:32.213Z","firstSeenAt":"2026-07-17T01:55:32.213Z","importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","sourceRecordId":"m8cf-pkii:2381912"}],"createdAt":"2026-07-17T01:55:32.213Z","updatedAt":"2026-07-17T03:14:43.105Z"}