{"id":"product-84531105fb028aeaa01a65bd","slug":"hayward-sp3207x10xe-230v-a01a65bd","kind":"model","name":"Hayward TriStar XE","manufacturer":{"id":"company-97e7f88c5898532e2bf572c9","name":"HAYWARD INDUSTRIES, INC."},"manufacturerCountryCode":"US","brandId":"brand:hayward","brand":"Hayward","modelNumber":"SP3207X10XE (230V)","partNumbers":[],"gtins":["0610377434454"],"wics":["04.1.001"],"relevance":"water","lifecycleStatus":"active","tier":0,"completeness":0.88,"href":"/api/v1/products/hayward-sp3207x10xe-230v-a01a65bd","web":"/en/products/hayward-sp3207x10xe-230v-a01a65bd","aliases":[],"familyId":"family-ab8eb786a26304e35b1b4256","familySlug":"hayward-tristar-xe-5b1b4256","officialUrl":null,"attributes":[{"key":"additional_model_information","label":"Additional Model Information","value":"TriStar XE,W3SP3207X10XE (230V)","valueType":"string","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"}},{"key":"product_type","label":"Product Type","value":"In-Ground (Self-Priming) Pool Filter Pump","valueType":"string","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"}},{"key":"motor_design","label":"Motor Design","value":"Multi-speed","valueType":"string","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"}},{"key":"reported_wef_kgal_kwh","unit":"kgal/kWh","label":"Weighted Energy Factor (WEF) (kgal/kWh)","value":9.3,"valueType":"number","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"}},{"key":"minimum_wef","label":"Minimum WEF for Federal Standard","value":"7.02","valueType":"string","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"}},{"key":"flow_gpm_at_low_speed_measurement_point","label":"Flow (GPM) at low speed measurement point","value":33.2,"valueType":"number","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"}},{"key":"head_fth20_at_low_speed_measurement_point","label":"Head (ftH20) at low speed measurement point","value":9,"valueType":"number","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"}},{"key":"rpm_at_low_speed_measurement_point","label":"RPM at low speed measurement point","value":"1560.51","valueType":"string","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"}},{"key":"power_w_at_low_speed_measurement_point","label":"Power (W) at low speed measurement point","value":139.27,"valueType":"number","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"}},{"key":"flow_gpm_at_high_speed_measurement_point","label":"Flow (GPM) at high speed measurement point","value":61.01,"valueType":"number","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"}},{"key":"rpm_at_high_speed_measurement_point","label":"RPM at high speed measurement point","value":2862.11,"valueType":"number","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"}},{"key":"head_ft_h20_at_high_speed_point","label":"Head (ft.H20) at high speed point","value":30.16,"valueType":"number","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"}},{"key":"power_w_at_high_speed_measurement_point","label":"Power (W) at high speed measurement point","value":"675.53","valueType":"string","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"}},{"key":"standby_average_power_w","unit":"W","label":"Standby Average Power (W)","value":4,"valueType":"number","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"}},{"key":"motor_construction","label":"Motor Construction","value":"Electronically-commutated Motor","valueType":"string","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"}},{"key":"hydraulic_horsepower_hhp","unit":"HHP","label":"Hydraulic Horsepower (HHP)","value":0.831,"valueType":"number","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"}},{"key":"rated_horsepower_hp","unit":"HP","label":"Rated Horsepower (HP)","value":1.25,"valueType":"number","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"}},{"key":"freeze_protection","label":"Freeze Protection","value":"No","valueType":"string","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"}},{"key":"connected_functionality","label":"Connected Capable","value":"No","valueType":"string","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"}},{"key":"date_available_on_market","label":"Date Available On Market","value":"2021-04-05T00:00:00.000","valueType":"string","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"}},{"key":"markets","label":"Markets","value":"United States, Canada","valueType":"string","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"}}],"certifications":[{"name":"EPA ENERGY STAR certified product","issuer":"U.S. Environmental Protection Agency","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","validFrom":"2021-03-31","identifier":"2375593","provenance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"}}],"status":"active","provenance":{"name":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"},"wics":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"},"brand":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"},"gtins":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"},"relevance":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"},"attributes":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"},"familyName":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"},"modelNumber":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"},"manufacturer":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"},"certifications":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"},"manufacturerName":{"ref":"EPA ENERGY STAR certified water products","method":"authorized_api","source":"government_dataset","retrieved":"2026-07-17","sourceUrl":"https://data.energystar.gov/resource/m8cf-pkii.json?pd_id=2375593","confidence":0.99,"importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","rawObjectHash":"f9dc61805df7d3575536bd69021478674b597b222ffc2ed79d4908daf58894b5","sourceRecordId":"m8cf-pkii:2375593"}},"sourceCoverage":[{"sourceId":"epa-energy-star-water-products","lastSeenAt":"2026-07-17T01:55:32.213Z","firstSeenAt":"2026-07-17T01:55:32.213Z","importBatch":"c5f586a0-b373-4c62-b0ca-7abf97177911","sourceRecordId":"m8cf-pkii:2375593"}],"createdAt":"2026-07-17T01:55:32.213Z","updatedAt":"2026-07-17T03:14:41.229Z"}